TOURNIQUET - DEFCON 5
  • TOURNIQUET - DEFCON 5
  • TOURNIQUET - DEFCON 5

TOURNIQUET - DEFCON 5

39.90
Tax included Product made to order generally delivered in 7/10 working days.

The CAT tourniquet is the CE-marked reference tourniquet for firefighters and police officers!

clear

Size Guide

This is an approximate conversion table to help you find your size. If you have already purchased an item from our brand, we recommend you select the same size indicated on its label.

Men's Sizes

International XS S M L XL XXL XXXL
Europe 32 34 36 38 40 42 44
US 0 2 4 6 8 10 12
Chest Circumference (inches) 33-35" 36-38" 39-41" 42-44" 45-47" 48-50" 51-53"
Chest Circumference (cm) 84-89 91-97 98-104 107-112 114-119 122-127 129-134
Waist Circumference (inches) 28" 30" 32" 34" 36" 38" 40"
Waist circumference (cm) 71 76 81 86 91.5 96.5 101.5

LOWA FOOTWEAR SIZE CHART

SIZE SELECTION:

THE SIZES IN THE DROP-DOWN MENU ARE UK SIZES (ENGLISH)

conversion chart: UK size - (IT size) - size in mm

Size 6.5 (40) 257mm

Size 7 (40 3/4) 262mm

Size 7.5 (41.5) 266mm

Size 8 (42) 270mm

Size 8.5 (42.5) 274mm

Size 9 (43 1/4) 278mm

Size 9.5 (44) 283mm

Size 10 (44.5) 287mm

Size 10.5 (45) 291mm

Size 11 (46) 295mm

Size 11.5 (46.5) 300mm

Size 12 (47) 304mm

Size 12.5 (48) 308mm

Size 13 (48.5) 312mm

NEED ADVICE ON CHOOSING A SIZE?

Take one of your sneakers and look at the size in mm or cm, look at the diagram above to see what it corresponds to and order your size!

e.g., your sneaker is 27.2 cm long? Great, the closest and most correct size will be: "TG 8.5 (42.5) 274mm", in the purchase menu select size 8.5UK!

Size Guide
Real time: 1 Visitor right now

Loyalty program By buying this product you can collect up to 3 loyalty points. Your cart will total 3 points that can be converted into a voucher of 0.60.


 
Quantity
on order!

Searching for hemorrhage is one of the first actions to take with any injured patient. It responds to C for catastrophic hemorrhage, also called M for massive bleeding or X for the 10 factor of coagulation.

Any bleeding must be stopped. Faced with anyone who is bleeding: Press, Extend, Alert and Cover!

It comes from the military field and allows you to apply the tourniquet yourself, using only one hand.

Description:

- Very effective in stopping arterial bleeding.

- Can be placed on an arm or thigh.

- CE standard tourniquet.

- Bar pressure resistance: 470 N.

- Bar deformation resistance: 17.7 mm.

- The compression bar is designed for a good grip thanks to its double grip cone.

- To facilitate the positioning of the tourniquet, the end of the band is yellow. Even in a dark environment, thanks to this warm color, you can locate the tip to stop the bleeding.

A tourniquet should always be ready for use!

General instructions for using the CAT tourniquet:

1- Open the tourniquet well and pass the tourniquet around the injured limb between the bleeding wound and the heart (at the root of the limb for the general public and according to the training received for trained professionals).

2- Pull the strap firmly and secure the device by folding it over itself.

3- Tighten around the arm, do not block the compression bar or the locking system.

4- Rotate the compression bar on itself until the bleeding stops.

5- Secure the compression bar in the locking system. The bleeding is stopped.

6- Secure the free part of the strap above the compression bar by passing the locking system to secure the entire device.

7- Close the white grip band above the locking system.

Leg bleeding: use with 2 hands

hands.

1- When the tourniquet is used on a leg, it must be placed on the thigh between the bleeding wound and the root of the limb. Pass the mobile strap around the thigh. Pass the free end through the inner return loop.

2- Then, pass the mobile strap through the outer return loop, then by friction, the strap will tighten.

3- Pull the strap firmly around the thigh and lock the device by gripping the strap on itself.

4- Rotate the compression bar on itself until the bleeding stops.

5- Lock the compression bar in the upper return of the locking system. The bleeding is stopped.

6- Close the white grip band above the locking system.

Using the friction cycle

When manually wearing the tourniquet, or when the tourniquet is too dirty, use the special shape of the friction buckle to secure the strap.

1- Pass the free end of the mobile strap through the inside of the buckle.

2- Then go back through the outer rear of the buckle, so that the grip strap is securely positioned.

3- Tighten the grip strap, tightened inversely.

IMPORTANT

Indicate on the white band the time and date of application – Never loosen an applied tourniquet – Call medical assistance (112) – Lie down and cover the victim.

Precautions for use:

1- Single use. Dispose of after use.

2- The use of this tourniquet requires trained medical or first aid personnel.

3- Read the user manual carefully before use.

4- Medical waste: to be disposed of in accordance with local regulations on the treatment of medical waste.

5- Must not be disposed of in household waste.

Storage:

Store at a temperature between 5°C and ~30°C, relative humidity not exceeding 80%, away from corrosive gases and in a ventilated room.

If these conditions are met, the validity is 5 years.

Dimensions:

Open length: 66 cm.

Folded length: 15.5 cm.

Width: 4 cm.

Folded thickness: 3 cm.

Weight (Kg): 0.10

YL-8412

Specific References

You might also like

TOURNIQUET - DEFCON 5

39.90